    when you do need power you need a special circuit.

    We also have a standard socket and a high power socket.

    Expect our normal outlets provide 230V 16A 3.5kW (3kW sustained) and the typical high power outlets outlets provide 400V 30A 11kW or 400V 60A 21kW.

    Which is why typical electric stoves here use 11kW and typical instant water heaters use 21kW.

    Though probably the most noticeable advantage is in electric car charging.

    • InverseParallax@lemmy.world
      link
      fedilink
      English
      arrow-up
      1
      ·
      3 days ago

      Yeah, in Sweden I charge our plug in hybrid off 240, it’s pretty quick and you can use any outlet.

      The giant round connectors are weird BTW, with all the holes, trying to sort that out for faster charging.

      I don’t think we should run 100+ volts everywhere, we need to standardize on lvdc in most places (basically usb-c or so) with 100v only in kitchens and places you need it, because it’s more dangerous and can cause fires more easily.

      • justJanne@startrek.website
        link
        fedilink
        English
        arrow-up
        1
        ·
        3 days ago

        That’s a common misconception. It’s the Amps that cause fires, not the voltage.

        The 5090 uses 600W, at 12V that’s 50A, but at 120V that’d only be 5A and at 240V only 2.5A.

        50A melts cables and burns your PC down, 2.5A won’t. The only risk of higher voltages is that they can jump across small air gaps much easier.

        • InverseParallax@lemmy.world
          link
          fedilink
          English
          arrow-up
          1
          ·
          edit-2
          3 days ago

          No it’s not, I’m an ee.

          P = I^2R, so power squares against the current, while it’s linear to voltage.

          This means current causes more heat dissipation in the wire, which has risks, potentially fire if you really go too far, this is why breakers trip.

          But what really causes fires (again, outside of crazy overcurrent) is Arcing, from basically either bad connections or bad insulation, OR, from an inductive load that gets disconnected, so the current tries to stay constant in the coils, which leads to massive voltage spikes.

          • justJanne@startrek.website
            link
            fedilink
            English
            arrow-up
            3
            ·
            3 days ago

            The recent technology connections video cited a lot of statistics on this topic, and at least household fires are primarily caused by overcurrent, not by arcing.

            You probably know more than me — I only studied compsci with ee as minor — but from my personal experience, I’ve seen many cases where overcurrent caused damage, burns or fire, but I can’t remember a single case where arcing caused actual damage.

            Even in cheap chinesium powerstrips, the primary cause of fires is overcurrent due to AWG 22 copper clad iron wire, not arcing. (Though the switches usually weld themselves together after a few dozen uses).