    Almost has to be. 2400W would put it completely outside the consumer market. Consumer PSUs don’t go that high. Home power outlets don’t go that high unless you have special electrical work done. I can hardly imagine what a cooling system for a nearly 3KW system would look like.

      • brot@feddit.org
        link
        fedilink
        English
        arrow-up
        3
        ·
        3 days ago

        Just imagine the costs of running such a system on European energy prices. We’re at ~0,35€/kWh here in Germany currently. That means that an hour of running this will cost you 0,84€. Add to that the energy use of the CPU, mainboard, Monitor and you’re paying well over 1€ per hour of gaming.

        • FurryMemesAccount@lemmy.blahaj.zone
          link
          fedilink
          English
          arrow-up
          2
          arrow-down
          1
          ·
          edit-2
          2 days ago

          Judges you from French 0.20€/kWh nuclear prices

          If only you guys had listened to the science… You’d be gaming AND heating your place for cheap!

          And regardless, unless the chip is radically different from what has been observed in currently available RTX 5090s, I don’t see how 2400W can be anything other than a transient spike

          • Zeoic@lemmy.world
            link
            fedilink
            English
            arrow-up
            1
            ·
            1 day ago

            The nuclear and hydro over here in Canada puts us around 0.10€/kwh on average. Really wish processes for nuclear were streamlined decades ago, power would be even better now if it was

          • brot@feddit.org
            link
            fedilink
            English
            arrow-up
            2
            ·
            2 days ago

            Let’s not start a discussion about nuclear energy here. France has enormous subvention on electricity and Germany a lot of taxes. And both countries have issues in their energy system, so yeah

            • FurryMemesAccount@lemmy.blahaj.zone
              link
              fedilink
              English
              arrow-up
              2
              arrow-down
              1
              ·
              edit-2
              2 days ago

              France has taken away electricity subventions a long time ago, they were temporary relief during COVID only.

              In fact, there are pretty high taxes here too, just the base cost is lower.

              And I started this debate to challenge the notion that all of Europe has Germany’s electrical management issues; they’re the main ones to have failed.

      • AnAmericanPotato@programming.dev
        link
        fedilink
        English
        arrow-up
        14
        arrow-down
        1
        ·
        3 days ago

        Oh! I knew European outlets operated at higher voltage, but I didn’t know the standard circuits supported such high current. Jealous!

          • CmdrShepard42@lemm.ee
            link
            fedilink
            English
            arrow-up
            16
            arrow-down
            1
            ·
            3 days ago

            And wiring is typically rated for current limits not voltage (within reason). Some 12 gauge wire doesn’t care if you’re pushing 12V, 120V, or 240V but is only rated for 20A.

            • kn33@lemmy.world
              link
              fedilink
              English
              arrow-up
              22
              ·
              3 days ago

              The easiest way to think about it is that the conductor is rated for the current, and the insulator is rated for the voltage. Now, once you get into the nitty gritty, they’re more intertwined than that, but it’s close enough for a surface level explanation.

        • PetteriPano@lemmy.world
          link
          fedilink
          English
          arrow-up
          8
          ·
          3 days ago

          I live in a 50 year old house. All the breakers are 16A, so 220V x 16A = 3.5kW

          The electric sauna does three-phase @ 400V. My energy tracker usually peaks around 9.5kW when it’s heating.

          • RejZoR@lemmy.ml
            link
            fedilink
            English
            arrow-up
            9
            ·
            3 days ago

            Most are actually 230V which is even more at standard 16A, 3680W to be precise.

            Countries that use 110V have so many weird limitations that we don’t even know in Europe. For them, 230V is the “special” outlet for special purposes.

            • InverseParallax@lemmy.world
              link
              fedilink
              English
              arrow-up
              1
              ·
              3 days ago

              Actually, in the US the outlets are often wired with 1 leg, while giving 2 legs gets you back to 240v.

              110 is probably better in terms of general safety (which is good because our houses are death traps), but it means when you do need power you need a special circuit.

              We should have both more common, but the plugs are terrible (basically they turn the left prong 90 deg).

              • justJanne@startrek.website
                link
                fedilink
                English
                arrow-up
                2
                ·
                3 days ago

                when you do need power you need a special circuit.

                We also have a standard socket and a high power socket.

                Expect our normal outlets provide 230V 16A 3.5kW (3kW sustained) and the typical high power outlets outlets provide 400V 30A 11kW or 400V 60A 21kW.

                Which is why typical electric stoves here use 11kW and typical instant water heaters use 21kW.

                Though probably the most noticeable advantage is in electric car charging.

                • InverseParallax@lemmy.world
                  link
                  fedilink
                  English
                  arrow-up
                  1
                  ·
                  3 days ago

                  Yeah, in Sweden I charge our plug in hybrid off 240, it’s pretty quick and you can use any outlet.

                  The giant round connectors are weird BTW, with all the holes, trying to sort that out for faster charging.

                  I don’t think we should run 100+ volts everywhere, we need to standardize on lvdc in most places (basically usb-c or so) with 100v only in kitchens and places you need it, because it’s more dangerous and can cause fires more easily.

                  • justJanne@startrek.website
                    link
                    fedilink
                    English
                    arrow-up
                    1
                    ·
                    3 days ago

                    That’s a common misconception. It’s the Amps that cause fires, not the voltage.

                    The 5090 uses 600W, at 12V that’s 50A, but at 120V that’d only be 5A and at 240V only 2.5A.

                    50A melts cables and burns your PC down, 2.5A won’t. The only risk of higher voltages is that they can jump across small air gaps much easier.

              • ExcessShiv@lemmy.dbzer0.com
                link
                fedilink
                English
                arrow-up
                2
                ·
                3 days ago

                110 is probably better in terms of general safety

                Eh, not really. There is no significant difference in safety between 110vac and 230vac. Voltage is not the (most) dangerous part, it’s the amps that kill if you’re electrocuted.

                • InverseParallax@lemmy.world
                  link
                  fedilink
                  English
                  arrow-up
                  3
                  ·
                  3 days ago

                  Amps are voltage over resistance (I = V/R), volts absolutely matter, the human body has a decent resistance and the higher voltage helps burn through that.

                  • ExcessShiv@lemmy.dbzer0.com
                    link
                    fedilink
                    English
                    arrow-up
                    1
                    ·
                    3 days ago

                    There’s a reason we talk about lethal current and not lethal voltage…30mA can kill you, even at something ridiculously low as 9V, but 5-10kV will not necessarily kill you, e.g. fences for horses will not kill you if you’re electrocuted by them because there’s basically no amperage. Voltage is not the determining factor in lethalness.

          • TWeaK@lemm.ee
            link
            fedilink
            English
            arrow-up
            3
            ·
            edit-2
            3 days ago

            Nominally EU voltage is 230V, and may be 240V. In fact, it can be as high as 230V +10% = 253V. Higher voltage means more power for a given current, so nominally it’s 16A x 230V = 3.68kW, but you could have say 16A x 250V = 4.0kW.

            If your sauna is 400V then it sounds like you’ll be 230V (400V / sqrt(3) = 230). But the voltage can also be 230V -6% = 216V, so 220V is within scope.

            But yeah, standard voltages in the EU are either 230V/400V or 240V/415V. They’ve been harmogenised, but if you look at the numbers you’ll see the trick - 230V +10% is roughly the same as 240V +6%. So the range is 230V-6% and 240V+6%.

            You’ve got a 3 phase connection though so you might find you’ve got different single phase breakers on different phases (eg lights on one phase, sockets on another), with slightly different voltages for each one.

        • OfCourseNot@fedia.io
          link
          fedilink
          arrow-up
          1
          ·
          3 days ago

          The installation in my home follows my country’s regulations as they were ~15 years ago. It’s divided into several circuits, the ‘general use’ outlets one is rated for 25A in total AND at any point, ie you could plug a 5750W appliance in any of those outlets. The lights circuit is the lowest rated at 15A, still letting you ‘plug’ up to 3450W.

        • lemmylommy@lemmy.world
          link
          fedilink
          English
          arrow-up
          2
          ·
          3 days ago

          I wouldn’t use that kind of power continuously. AFAIK the sockets are supposed to handle 16A for at least six hours, when they are new. When charging your car on Schuko sockets it’s good practice to limit it to 10A and check for the socket temperature after a while. Also, any connections in the cabling can have increased resistance with age and heat up with heavy continuous use. That shouldn’t matter that much when running a kettle or toaster for a few minutes, but charging a car or gaming for hours can become a problem.

        • Da Bald Eagul@feddit.nl
          link
          fedilink
          English
          arrow-up
          3
          ·
          3 days ago

          3840W per breaker. Minus 2400 leaves 1440W, for a CPU, the minor components, and monitors/other equipment. In theory it could work.

          • Ilovethebomb@lemm.ee
            link
            fedilink
            English
            arrow-up
            1
            ·
            3 days ago

            You would still need to run the computer off multiple plugs, as almost any 240v plug is 10a.

            You’d likely need a dedicated breaker and plug, similar to a stove plug.

            • Da Bald Eagul@feddit.nl
              link
              fedilink
              English
              arrow-up
              2
              ·
              3 days ago

              Here, plugs are 230V and 16A = 3680W. Not quite as much as I thought (most extension cords seem to be rated for a bit more, which makes sense), but definitely enough to run monitors of the same breaker.

            • Evil_Shrubbery@lemm.ee
              link
              fedilink
              English
              arrow-up
              2
              arrow-down
              1
              ·
              edit-2
              3 days ago

              Yes, your are right, here is a map of Europe where you have chad power plugs in a-Murika (outside these towns only virgin plugs):

          • roofuskit@lemmy.world
            link
            fedilink
            English
            arrow-up
            1
            arrow-down
            4
            ·
            3 days ago

            God forbid I supply information. I’m fucking done commenting with all you over sensitive weirdos who think everything is a fucking argument.

    • NuXCOM_90Percent@lemmy.zip
      link
      fedilink
      English
      arrow-up
      4
      ·
      3 days ago

      nVidia cares less and less about the consumer market every year. We basically only exist to buy the factory fourths so that the overall yield of any given wafer can be maximized.

      2400 for a single component is still rather insane even by server room standards. But 12 or even 18 load balanced? That starts to “make sense” for higher end data centers or even on-prem server rooms at the more tech oriented companies.